Sign In | Join Free | My himfr.com
Home > Electrical Test Equipment >

Coupler Line Temperature Rise Test Equipment With Three Core Rubber Insulated Cord

    Buy cheap Coupler Line Temperature Rise Test Equipment With Three Core Rubber Insulated Cord from wholesalers
     
    Buy cheap Coupler Line Temperature Rise Test Equipment With Three Core Rubber Insulated Cord from wholesalers
    • Buy cheap Coupler Line Temperature Rise Test Equipment With Three Core Rubber Insulated Cord from wholesalers

    Coupler Line Temperature Rise Test Equipment With Three Core Rubber Insulated Cord

    Ask Lasest Price
    Brand Name : Kinte
    Model Number : WH-8819D
    Certification : Certificate of conformity of quality management system certification
    Price : Customized
    Payment Terms : L/C, T/T
    Supply Ability : Customized
    Delivery Time : Customized
    • Product Details
    • Company Profile

    Coupler Line Temperature Rise Test Equipment With Three Core Rubber Insulated Cord

    Coupler Line Temperature Rise Test Equipment With Three Core Rubber Insulated Cord


    Scope of application: in line with IEC60320-1998.18 and GB17465-1998.18 and the national


    standard of the technical standards for the design, for thermal conditions and thermal conditions


    under the heat of the appliance coupler test.


    That is to say, appliance couplers for use in hot and hot conditions shall be capable of


    withstanding the heat generated by the apparatus or equipment to which they are connected or


    for the construction of connectors for thermal and thermal conditions, Insulation will not overheat.


    Test purpose: The rewirable connector shall be fitted with a three-core rubber insulated cord with


    a cross-sectional area of ​​1.5 mm2. The non-rewirable connector shall be tested at the time of


    delivery. The connector was inserted into the appliance input socket of the test device for 4 days


    (96 hours).


    The temperature of the pin base is maintained at 120 ° C ± 2 ° C for the entire duration of the


    test, for use in connectors under thermal conditions; 155 ° C ± 2 ° C for connectors under extreme


    heat conditions. 2) Working current: 10A; 3) Test temperature range: 0 ~ 199 ℃; 4) Temperature


    meter accuracy: ± 2% ± 2d; 5) Time (1) Input voltage: AC: 220V ± 10% / 50Hz; Timer: 0.01S ~


    99H99min; 6) equipped with high-precision K-type thermocouple.